Laboratory animals often need to be catheterized for repeated blood sampling, such as for pharmacokinetic studies, or for infusion of test compounds. Researchers use lock solutions to keep the catheter patent (free of blockages such as blood clots) when they will not be accessed for a long time, such as the days when the animal is recovering from surgery. Flush solutions are used in the process of accessing the catheter: withdrawing the lock solution, checking patency, pushing in a bolus dose or clearing blood remaining in the catheter after sampling. Often flush solution is left in the catheter if the time to the next dose or sample is not long enough that the catheter is expected to lose patency (a time period that is greatly influenced by the vessel, surgical technique, catheter material and whether the catheter system is closed and subcutaneous).
The approach to flush and lock solutions varies greatly from one lab to the next; there is little standardization on the formulation. Some prepare them in-house under conditions ranging from an open lab bench to the highly controlled environment of a pharmaceutical company formulation department. Others purchase the solutions pre-made from clinical suppliers, or from suppliers that focus on the specific needs of laboratory animal research. But how do you know which is right for you?
At Instech we have made the “plumbing” for rodent infusion and sampling for 50 years — swivels, tethers, catheters — but we are a new supplier of the stuff that runs inside these pipes. As part of the launch of our line of pharmaceutical-grade flush and lock solutions for research we reviewed key factors to consider when selecting catheter maintenance solutions:
Heparinized glycerol or dextrose? TCS? What is the best heparin concentration? Unfortunately there is no clear answer. The protocol, species, surgery and catheter system can all influence which is right for you. However, you’re not left to fend for yourself entirely. This post takes a deeper look at the various formulations and what might be used when.
Does it meet the standards set by the USP to be considered "pharmaceutical-grade"? Is it supplied sterile, and can you maintain that sterility until it is injected? There’s a lot to consider here.
The prefilled syringes you buy should have no air bubbles in them, otherwise you’ll have to spend time clearing them out before you access the catheter. If the air has entered the syringe because the tip is not sealed, not only is the solution probably not sterile, but the drug concentration will have changed due to evaporation.
NIH's Office of Laboratory Animal Welfare states: OLAW and USDA agree that pharmaceutical-grade substances, when available, must be used to avoid toxicity or side effects that may threaten the health and welfare of vertebrate animals and/or interfere with the interpretation of research results. See this guidance document here for more information.
AAALAC International states: Whenever possible, pharmaceutical-grade compounds must be used [for clinical use]. If available, and suitable, pharmaceutical-grade compounds are preferred [for research use].
If you are using non-pharmaceutical-grade flush or lock solutions, your IACUC should require a justification.